Thoroughly clean the roof surface. Roofs collect oils from asphalt, chimneys, and cars plus lots of dirt and dust. Coatings don’t stick well to any of these. We recommend cleaning with an inexpensive solution of TSP or TSP Substitute in a bucket of water (follow label instructions). Use a broom to scrub ponding areas and areas of peeling coatings. Work a section at a time and hose off the dirty water. Sweep away puddles to promote drying. Do not allow wash water to dry on walls, furniture, windows, and visible surfaces. 
Wallis knows proper application of urethane products is paramount in have an effective insulation barrier. Insulation performance is also based on the R Value provided. Our minimum application is always more than adequate to give a proper R value. Wallis will never skimp on applying product. We make sure you receive what we promise as a minimum. Wallis always does a proper application of material with out worry of insulation thickness or performance. We always make sure that you are receiving the Thermal Break from heat and cold that is expected and appropriate for your needs.
Q. "I talked to a building product supplier for WALLTITE spray foam, he is suggesting to use 2" or 3" of closed cell-spray foam in the joists areas instead of the batts insulation. He says it will work with outboard rigid insulation. There is a location of a cantilevered floor area with steel beam so I may need to use spray foam to protect the steel beam. It would then be convenient continue to spray in the floor joist cavities and then apply 5" of polyiso outboard of the bottom cantilever floor sheathing."

Spray Foam Companies


Repair and seal roof penetrations, tears, open seams, etc. using Elastek 103 Crack & Joint Sealant and reinforce with polyester roof fabric as necessary. In larger or deep ponding areas, apply Elastek 500 Puddle Plaster to fill in areas that hold water. Avoid using plastic roof cement. Serious ponding should be referred to a roofing contractor. Blisters in previous coatings may be opened but these areas must be allowed to dry-out completely. Blisters in the roofing ply should be left alone unless likely to break. Caulk and reinforce open seams, roof penetrations, cracks, and tears. These are potential leak points so work carefully and thoroughly. Use fabric to build flashings around roof edges or roof penetrations, and to reinforce various coating repairs. A polyester fabric is used because it will stretch with the coatings. (Fiberglas fabric is not recommended.) Fabric is normally cut to extend three inches beyond the repaired area in all directions. The coating is applied to the roof surface and the fabric is immediately pushed into the wet surface. An additional coat is applied over the fabric and the patch is allowed to dry. If your roof has stucco parapets, examine them for cracks along the sides and top. These areas often permit water to enter the wall and can cause blisters and wrinkles in the roof surface. Repair with Elastek 103 Crack & Joint Sealant. If you do not have parapets, examine the metal drip edge for a tight seal with the roof membrane. Use 4″ or 6″ roofing fabric covered under and over with Crack & Joint Sealant to seal cracks along drip edges, penetrations, and open seams. https://m.youtube.com/watch?feature=player_embedded&v=ggLAUsiuI_o
A. You can use closed-cell spray foam that way if you want, although you should realize that the spray foam will prevent the roof sheathing from drying inward. This approach should only be used if the roof sheathing is bone dry, because it will never dry when sandwiched in this manner. Most building scientists would prefer to see fiberglass rather than closed-cell spray foam under the roof sheathing in this type of assembly.

Jennifer, I'm not an expert on the health effects of closed cell foam. A lot of people live in houses with closed cell foam and have no health problems from it, at least not short-term, acute problems. I do know of one person who had it removed from her crawl space because she was convinced it caused her dog to get sick, but I know only what she told me.   http://www.youtube.com/v/ggLAUsiuI_o&feature=share
Spray foam insulation, when properly installed is both an air barrier and when closed cell foam is used at the proper depth a vapor barrier!  Before hiring any contractor you should establish the brand of foam being used and verify that with the named manufacture.  Please ask for ESR reports and MSDS sheets on any foam being installed in your home. A couple areas where you might consider spray foam insulation include: 

We love the Heng’s rubber roof coating because it is versatile enough to work on the RV roof and protects it from the elements longer than other products do. Plus, it is useful enough to be used in sealing seams and tears. Versatility does matter when shopping around for an RV roof coating. It ensures more uses, meaning more value for the money. That said we don’t need to buy a separate product to perform the tasks.
Most closed-cell spray foam is now formed using hydrofluorocarbon (HFC) blowing agents that have high global warming potential, partially or completely offsetting the climate benefits of the energy savings they can offer. In the United States, HFCs are scheduled to be phased out by January, 2021. A few spray foam suppliers have started supplying spray foam blown with hydrofluoroolefin (HFO) blowing agents without this problem as of early 2017.[14]

Simple – we’ve seen experienced contractors work with the separate nitrogen tanks and spray foam rigs and have one heck of a time. These spray foam insulation kits are quick to learn and simple to use. They’re designed to be easy so you get results the very first time you spray. Thorough Instructions, 24/7 Product Support, and videos make it easy to install.

The problem you saw with the closed cell foam pulling away like that is due to the heat of the foam was to hot. It was actually curing out and making foam before it could adhere to the wood. The installer wasn't reading his foam correctly. He should of stopped and turned down the heat on his hose temp. Also installers have to be aware that as the sun rises and the temp in attics rises the subtrates get hotter as well. This will cause the installer to adjust his heat when installing the foam as the temp changes thru out the day.  
I started using Gaco years ago primarily to solve ponding water Problem. It has work well, solved my problems with other roofing options and repairs as well as many other Flat roof issues.  My only problems were experienced when I did not clean the surface well enough for good adhesion.  Follow the Instructions.  Great product and highly recommended. .
Empire Spray Foam is conveniently located in North Texas and proudly serves the Tarrant, Dallas, Denton, Wise, Parker, Hood, Johnson, Ellis, Kaufman, Rockwall, and Collin Counties with high quality spray foam and coatings designed to meet the needs of homeowners and businesses. Whether you are looking for energy savings, structural reinforcement, or weatherproofing, we have the solution. Call today to discuss your spray polyurethane foam options 817-516-2014.
When it comes to weatherproofing your RV roof, the Flex Seal liquid roof is one of those we’re proud to recommend because it can be applied in all temperatures. It can also protect your camper roof from even the harshest weathers, including rain, snow and wind. With it, you can keep your roof protected from changing temperatures, eventually prolonging its lifespan.

This depends on the geographic location, insulation, and cost of electricity. Lawrence Berkeley National Laboratory (LBNL), Oak Ridge National Laboratory (ORNL), National Roofing Contractors Association (NRCA), and several roofing material manufacturers have computer programs that can estimate the savings. A growing number of energy consultants are available to provide environmental regulation compliance information. http://www.youtube.com/v/ggLAUsiuI_o?version=3
A: The RV roof coating works by waterproofing, weatherproofing and sealing our RV roofs from elements, including rain, snow, wind and other outer forces. It can also resist impact from leaves, twigs, dusts and other things that would otherwise damage the roof. It also works by reflecting UV rays, keeping the roof from degradation. The roof coating can also prevent leaks, heating and cooling loss and discomfort in our RV. https://www.youtube.com/watch?feature=youtu.be&v=ggLAUsiuI_o
Current guidelines recommend up to 10 inches of insulation in your attic . This is usually added to the ground, rather than the roof line, which results in the loss of your storage area, due to not being able to refit floor boards after installation. By implementing spray foam insulation to the roof line, you regain the lost 10 inches, thus increasing storage, height and practicality.

Fort Worth, Arlington, Denton, Lewisville, North Richland Hills, Haltom City, Weatherford, Flower Mound, Keller, Grapevine, Bedford, Euless, Granbury, Hurst, Stephenville, Carrollton, Mineral Wells, Frisco, Azle, Crowley, Southlake, Rhome, Haslet, Aubrey, Colleyville, Dublin, Grand Prairie, The Colony, Dallas, Lake Dallas, Sanger, Kennedale, Little Elm, Roanoke, Decatur, Pilot Point, Mansfield, Poolville, Aledo, Argyle

There is a significant price difference when it comes to using foam insulation to insulate a new versus older home. Spraying insulation inside a newly constructed home is easier because the installation company can ensure the insulation will work effectively and design it for optimum defense against sound, heat transfer and utility costs. Installing spray foam in older homes that contain existing insulation can cost additional time and money -- it is not usually recommended as compared to weatherization or an energy aduit.
Spray foam is a very specialized packing material, often required for use in shipping valuable fragile items. Engineered packaging principles are designed to protect sculptures, vases, large fossils, lamp bases, busts, computers, furniture, chandeliers and other objects of unusual shape. By virtue of the liquid foam expanding by up to 30-60 times the volume of its liquid state, it efficiently protects almost any size, form and weight.

Henry 287 Solar-Flex White Roof Coating is a Henry 287 Solar-Flex White Roof Coating is a premium elastomeric water-based acrylic latex coating designed to reflect the sun's heat and UV rays. Properly applied it is highly resistant to disbonding chalking mildew and discoloration. Expands and contracts with your roof to protect it from leaks aging mold mildew and ...  More + Product Details Close
I just received this and it worked well for me. It works well for small gaps (around windows, between studs), but probably not the right tool for larger gaps (>1" or 2"). If used in larger gaps, it works OK if it is layered in. Spray a little and wait for it to set, then layer another on top, etc... This is pretty much noted by the seller. It is pretty much exactly as described and priced right, so 5 stars. If you need to do larger gaps, buy 2 part.
If your foam pulled away just a little bit, Jamie, and they were able to fix it with just a little bit of touching up, then it wasn't as bad as the house where I saw this problem. As the last photo above shows, it had pulled away significantly from the studs and rafters, and it was all over the house. This was closed cell foam, and interestingly, it didn't pull away from the horizontal framing members, just the vertical and sloped ones. They did some touch up, but that wasn't enough. I don't know how this one ended up getting resolved. I think maybe the contractor came back and sprayed cellulose on top of the foam.
The complete line of JM open- and closed-cell spray foam insulation solutions provide superior thermal and energy performance, as well as advanced air, moisture and sound control in any climate. These products can be used in interior and exterior walls, unvented and vented attics, floors, ceilings and crawl spaces. Plus, using spray foam can reduce air leaks and create a more comfortable, energy-efficient home – meaning you could see more energy savings every month.
FROTH-PAK Foam Sealant is a two-component quick-cure polyurethane FROTH-PAK Foam Sealant is a two-component quick-cure polyurethane foam that fills cavities penetrations cracks and expansion joints. FROTH-PAK foam sealant can also be used as a sealant and void fill in many roofing applications. FROTH-PAK is chemically cured foam which significantly reduces curing time. FROTH-PAK dispenses expands and becomes tack ...  More + Product Details Close
OK, Peter, I finally went back and read Alex Wilson's article on what he perceives as a serious problem. I haven't seen the full report, but based on the summary he wrote on the Green Building Advisor website, I question the science. It seems to me that he's chosen the wrong metric and he's basing his conclusion on too many assumptions because he doesn't have enough data. You can see my comments at the end of his article. http://m.youtube.com/embed/ggLAUsiuI_o
Whether you’re sending something fragile in the mail or keeping valuables safe during a move, secure packing is everything. To protect a delicate item, simply fill a spare shopping bag half-full with spray insulation foam and place in the bottom of a box, pressing the item gently into the bag as it hardens to cushion the item. Repeat for the top and you have a DIY custom packaging solution that can handle the rigors of delivery.
Note: The practice of foam insulating the attic has raised eyebrows in the building industry because "standard" roofing techniques call for the attic to be ventilated; however, in a vented attic situation it will become approximately 130 degrees in the summer. There's no reason for an air-conditioning and vent-ductwork to have to work in that type of severe conditions. By applying Icynene right on the underside of the roof deck, the severe temperatures no longer exist in the attic. In short, the attic is now a "conditioned" space of the house that is just as comfortable as any other room in the home. This is called a "Compact Roof", which means you can frame right up against it. The one drawback of using expanded foam on the inside of the roof is that this will cause the temperature of the shingles to rise, but how much is not yet known. And how much damage a rise in temperatures could cause is debatable.
As this example illustrates, it's important to seal the envelope completely. One of spray foam's biggest selling points is its air-sealing ability, but it can't seal places where it's not sprayed. One of the nice things about using spray foam in new construction is that you can do a Blower Door test before the drywall goes in. Even better, you can test for leaks with a fog machine. http://m.youtu.be/ggLAUsiuI_o
Today, each of the 50 states follows a different set of building codes making navigating these codes confusing, particularly for architects or builders that have projects in multiple states. In some cases, the building code changes significantly between the state and certain cities or counties within the state. For example, at the time of writing Arizona had adopted the 2015 IRC Building Code, however, Phoenix was on the 2012 IRC, IBC and IECC code. With the majority of states either on the 2009, 2012 or 2015 code, below are some high-level points to consider and about how spray foam insulation contributes.
Loctite tite foam is a new generation of Loctite tite foam is a new generation of polyurethane-based insulating foam sealant that expands to fill seal and insulate gaps and cracks inside or out. It is white polymer foam based on purified and concentrated ingredients that provides 4 times more density versus conventional foams for better durability and insulation. ...  More + Product Details Close
Apply coating when the roof is dry and the sealant has set. You will be using a 9-inch heavy-duty frame, ½-inch paint roller for spreading coating on roof or 1-1/4-inch roller for dipping in pail, and a 5–to-6-foot extension pole. Use a 3/4-inch roller with basecoats and emulsions. Map out your roof and make each pail fill that area. See Elastek Product Sheets for recommended coverage. An inexpensive 3-inch or 4-inch brush should be used to reach areas not possible with a roller. Use a stiff paintbrush for applying 103 Crack & Joint Sealant.

Water-based acrylic coatings have more than 30 years of proven performance over a wide range of substrates. It is the coating of choice for metal roofs since it is highly reflective, can be easily tinted and is not extremely slippery when damp. When used with our rust primer, even rusted roofs can be saved. TIP: If you have a metal roof or a low slope roof that doesn't pond water, consider acrylic coatings.

How Much Better Is Spray Foam Insulation


Note:  A board foot is defined as a 12" x 12" square at 1" thick. Actual output can be affected by a number of factors including temperature and humidity. The theoretical yield has become an industry standard for identifying certain sizes of two component kits. Theoretical yield calculations are performed in perfect laboratory conditions, without taking into account the loss of blowing agent or the variations in application methods and types. 

I have used the Froth-Pak 200 to air-seal rim joists--the area above the foundation wall in a basement. The first time I used it I did not shake the canisters well enough and the foam did not cure properly. Don't just shake the box for a few seconds. I take the tanks out of the box so I can shake/invert each tank for a minute or two. You will be able to hear the chemical sloshing around in the tanks. Also, don't ignore the recommended temperature for application--around 75 degrees F.
You've got no argument from me there, Dennis. Getting a good installer if you're going with spray foam is crucial. Many builders or homeowners don't know how to find one, however, and that's where third party inspections come in. Also, even good installers have bad days, but if someone comes in behind them with a measuring probe and a Blower Door, there will be fewer sub-par foam jobs.  
For large jobs, professionals such as Dr. Energy Saver use two-part foam, which comes in larger containers. With 2-part spray foam, it's necessary to mix separate resin and catalyst compounds at the application nozzle. Combining these ingredients starts a chemical reaction that creates expanding foam. Contractors use small 2-part foam "kits" to air-seal an attic or to seal and insulate ductwork. To insulate an entire attic or wood-framed wall with spray foam, the resin and catalyst compounds are pumped to the application nozzle from 50-gallon drums in a specially equipped truck.

How Much Is Spray Foam Per Sq Ft

×