Please Note: Prices, promotions, styles and availability may vary by store and online. Inventory is sold and received continuously throughout the day; therefore, the quantity shown may not be available when you get to the store. This inventory may include a store display unit. Online orders and products purchased in-store qualify for rebate redemption. Mail-in Rebate is in the form of merchandise credit check, valid in-store only. Merchandise credit check is not valid towards purchases made on MENARDS.COM®. By submitting this rebate form, you agree to resolve any disputes related to rebate redemption by binding arbitration and you waive any right to file or participate in a class action. Terms and conditions available at www.rebateinternational.com®
One of the best ways to achieve it is to use the Heng’s rubber coating that can protect it from the elements, including sleet, wind, rain, and snow and UV rays. The product also does well in keeping our roof protected from dirt, leaves and twigs. With such protection received, our roof won’t degrade and we prevent ruining our recreational vehicle investment.
The product is an acrylic coating, which is packed conveniently for ease of use. As it is also in one-gallon size, you can rely on its supreme area coverage reaching up to 125 square feet. The Dicor rubber roof coating is also very easy to apply. When shopping around for a roof coating, we believe it pays off to find an easy to apply product for fast results. It is one of the best qualities of the RV roof coating that makes it a top pick in the category. http://www.youtube.com/watch?feature=youtu.be&v=ggLAUsiuI_o
Today, each of the 50 states follows a different set of building codes making navigating these codes confusing, particularly for architects or builders that have projects in multiple states. In some cases, the building code changes significantly between the state and certain cities or counties within the state. For example, at the time of writing Arizona had adopted the 2015 IRC Building Code, however, Phoenix was on the 2012 IRC, IBC and IECC code. With the majority of states either on the 2009, 2012 or 2015 code, below are some high-level points to consider and about how spray foam insulation contributes.
This tropic heat actually is the cause that the steel structure, which most roofs in that part of the world are built on, expands and contracts all the time. By doing so, the sun-battered steel structure causes the roof tiles to dislodge and slowly creates small openings between the roof tiles, through which rain water can run into, creating leaks that can cause much damage to plastered ceilings and electric wiring.

Spray Foam Contractors


After researching this, Im curious about a method called poor mans sprayfoam where foamboard is cut to size between studs and sprayfoamed around the perimeter. Aside from the labour doing the job yourself, the cost seems comparable, is one better than the other? What about the quality of the canned sprayfoam around the perimeter? When i see sprayfoam done, it is never a full depth of the studs, so you would get 2.5-3 inches in a 3.5" (2x4) wall. Any thoughts? 

Spray Foam Roofing


The problem you saw with the closed cell foam pulling away like that is due to the heat of the foam was to hot. It was actually curing out and making foam before it could adhere to the wood. The installer wasn't reading his foam correctly. He should of stopped and turned down the heat on his hose temp. Also installers have to be aware that as the sun rises and the temp in attics rises the subtrates get hotter as well. This will cause the installer to adjust his heat when installing the foam as the temp changes thru out the day.   https://m.youtube.com/e/ggLAUsiuI_o


The Gardner 4.75 Gallon Heavy Duty Foundation Coating The Gardner 4.75 Gallon Heavy Duty Foundation Coating is ideal for sealing concrete block and poured foundations fence and deck posts retaining walls and metal surfaces. Its high penetrating seal resists damage and deterioration due to moisture and insects. When applied properly this solvent-based asphalt coating helps prolong the life ...  More + Product Details Close http://m.youtube.com/watch?v=ggLAUsiuI_o

Spray polyurethan foam does effectly prevent all six of these heat transfer methods from occurring. These should be the mechanisms by which you judge insulation, in addition to their R-Value. If you're uncertain about installing spray foam insulation, Energy Star has a map that recommends levels of insulation by R-value and cost-effectiveness in the United States. 

I was hesitant to buy this because many reviews stated that it didn't cover as advertised, but after reading/following all directions, everything turned out perfectly. It even seemed to apply slightly more than the 650 bd/ft that was advertised. The application process was very easy to learn and I applied all of the product in about 1 hour and 10 minutes- prep time included. I couldn't be happier and I purchased another kit this morning.

How Much Is Spray Foam Roof Insulation


After researching this, Im curious about a method called poor mans sprayfoam where foamboard is cut to size between studs and sprayfoamed around the perimeter. Aside from the labour doing the job yourself, the cost seems comparable, is one better than the other? What about the quality of the canned sprayfoam around the perimeter? When i see sprayfoam done, it is never a full depth of the studs, so you would get 2.5-3 inches in a 3.5" (2x4) wall. Any thoughts? 

Spray Foam Roofing


OK, Peter, I finally went back and read Alex Wilson's article on what he perceives as a serious problem. I haven't seen the full report, but based on the summary he wrote on the Green Building Advisor website, I question the science. It seems to me that he's chosen the wrong metric and he's basing his conclusion on too many assumptions because he doesn't have enough data. You can see my comments at the end of his article. http://youtube.com/watch?feature=youtube_gdata&v=ggLAUsiuI_o
Wallice Foam did a fantastic job on our new home and my little she shed. While in the process of backing in our extremely difficult driveway with their unit our mailbox was accidentally knocked over, and they were there within three hours that same day and brought a crew to repair and set back up our mailbox, we greatly appreciate there honesty and their willingness to repair our mailbox and so promptly. We would highly recommend this company for any foam insulation needs you may have. The *****’s
This website uses cookies and other tracking technologies (also known as pixels or beacons) to aid your experience (such as viewing videos), as well as “performance cookies” to analyze your use of this website and to assist with marketing efforts. If you click the "Accept All Cookies" button or continue navigating the website, you agree to having those first and third-party cookies set on your device. If you do not wish to accept cookies from this website, you can choose to not allow cookies from this website by updating your browser preferences. For more information on how we use Cookies, please read our Privacy Policy   Accept All Cookies

Spray Foam Insulation Cost


Excellent kit for insulating a house. Slow rising foam takes longer to insulate an area as you must do it in layers 1" thick. Any thicker can overheat the chemicals and prevent a proper cure and off-gassing. Recommend purchasing a second suit and nozzles so you can use it multiple days to achieve the thickness desired for the highest R value. Seals up and insulates much better than traditional fiberglass. The sound suppression is noticeably different. Used it to insulate the ceiling above our bedroom. The sound is remarkably more quiet than the fiberglass insulation we had before. The only down side is the weight of the containers. Using a smaller kit would be easier to handle and move around when spraying a ceiling in an attic. A word of caution, use plywood that spans at least 2 joist per container when spraying in an attic to hold the weight.

How Much Is Spray Foam Roofing


We are turning our roof into an unvented roof assembly by raising the roof and blowing in SPF. We are planning to leave the existing vapor barrier down but remove the fiberglass batting and then adding 6" of SPF in all the cavities, to completely seal and insulate the house. Should we have any concerns about doing it "upside down" and not spraying the foam directly to the underside/sheathing of the roof? https://www.youtube.com/watch?v=ggLAUsiuI_o&app=mobile
Q. "I talked to a building product supplier for WALLTITE spray foam, he is suggesting to use 2" or 3" of closed cell-spray foam in the joists areas instead of the batts insulation. He says it will work with outboard rigid insulation. There is a location of a cantilevered floor area with steel beam so I may need to use spray foam to protect the steel beam. It would then be convenient continue to spray in the floor joist cavities and then apply 5" of polyiso outboard of the bottom cantilever floor sheathing." http://www.youtube.com/watch?feature=youtube_gdata&v=ggLAUsiuI_o
Wallis knows proper application of urethane products is paramount in have an effective insulation barrier. Insulation performance is also based on the R Value provided. Our minimum application is always more than adequate to give a proper R value. Wallis will never skimp on applying product. We make sure you receive what we promise as a minimum. Wallis always does a proper application of material with out worry of insulation thickness or performance. We always make sure that you are receiving the Thermal Break from heat and cold that is expected and appropriate for your needs.

If your foam pulled away just a little bit, Jamie, and they were able to fix it with just a little bit of touching up, then it wasn't as bad as the house where I saw this problem. As the last photo above shows, it had pulled away significantly from the studs and rafters, and it was all over the house. This was closed cell foam, and interestingly, it didn't pull away from the horizontal framing members, just the vertical and sloped ones. They did some touch up, but that wasn't enough. I don't know how this one ended up getting resolved. I think maybe the contractor came back and sprayed cellulose on top of the foam.
We have a 22 year old home located in southeastern georgia where the humidity is very high. In the past 2 weeks our floors have started buckling all over. We have a vented crawl space and the old insulation is drooping from moisture and the wood is wet. We are debating between the "encapulation" method or the spray foam method to repair this issue. Which would you recommend?
OK, Peter, I finally went back and read Alex Wilson's article on what he perceives as a serious problem. I haven't seen the full report, but based on the summary he wrote on the Green Building Advisor website, I question the science. It seems to me that he's chosen the wrong metric and he's basing his conclusion on too many assumptions because he doesn't have enough data. You can see my comments at the end of his article. http://youtube.com/watch?feature=youtube_gdata&v=ggLAUsiuI_o
Spray foam is available in two different types: open-cell spray foam which is usually $0.44 to $0.65 per board foot and closed-cell spray foam which is about $1 to $1.50 per board foot. The average cost to have spray foam professionally installed is about $2,316. This number can vary depending on whether the home being insulated is newly constructed. However, finished homes are not a good candidate for spray foam insulation but great for weatherization or an energy audit.   https://youtube.com/embed/ggLAUsiuI_o
Wallice Foam did a fantastic job on our new home and my little she shed. While in the process of backing in our extremely difficult driveway with their unit our mailbox was accidentally knocked over, and they were there within three hours that same day and brought a crew to repair and set back up our mailbox, we greatly appreciate there honesty and their willingness to repair our mailbox and so promptly. We would highly recommend this company for any foam insulation needs you may have. The *****’s
Solvent-based polyurethane coatings have excellent adhesion and when used as a base coat over asphalt, EPDM, TPO or PVC, it eliminates the need for a primer. The resulting savings on labor and material more than offsets the higher cost of the product. When top coated with silicone, it gives you the best of both worlds. It's also an excellent gutter and RV coating.
c) Make sure that the over expanded access is properly removed from the walls. We had a junior cutter taking too much off by bending his saw into the cavity. Look closely at the inside wall corners, and ceiling/wall corners to make sure that the foam is properly removed flush with the studs. If it has not been cut back flush it may lead to uneven drywall finishes .

Please Note: Prices, promotions, styles and availability may vary by store and online. Inventory is sold and received continuously throughout the day; therefore, the quantity shown may not be available when you get to the store. This inventory may include a store display unit. Online orders and products purchased in-store qualify for rebate redemption. Mail-in Rebate is in the form of merchandise credit check, valid in-store only. Merchandise credit check is not valid towards purchases made on MENARDS.COM®. By submitting this rebate form, you agree to resolve any disputes related to rebate redemption by binding arbitration and you waive any right to file or participate in a class action. Terms and conditions available at www.rebateinternational.com®


Fort Worth, Arlington, Denton, Lewisville, North Richland Hills, Haltom City, Weatherford, Flower Mound, Keller, Grapevine, Bedford, Euless, Granbury, Hurst, Stephenville, Carrollton, Mineral Wells, Frisco, Azle, Crowley, Southlake, Rhome, Haslet, Aubrey, Colleyville, Dublin, Grand Prairie, The Colony, Dallas, Lake Dallas, Sanger, Kennedale, Little Elm, Roanoke, Decatur, Pilot Point, Mansfield, Poolville, Aledo, Argyle
Another thing we love about the Liquid Roof is its ability of not being damaged by freezing and other extreme temperatures. You will also appreciate its ability of staying flexible for a longer period of time. Did you know that it could also contract and expand as you roof moves? That is one of the things to look for when shopping around for this kind of product we found in the Liquid Roof.

Spray Foam Crawl Space


Most flat roofs are not perfectly sloped, causing water to puddle in some areas, in particular around the drains and scuppers. Many roof coatings are not rated or warranted for "ponding water", and thus might fail pre-maturely if exposed to standing water over long periods of time. Serious consideration should be given to the performance and limitations of the coating being selected. Some manufacturers will warranty their coatings including ponding water. Typically, manufacturers for acrylic roof coatings do not include warranties for ponding water, while some polyurethane and silicone roof coatings manufacturers will. https://youtu.be/ggLAUsiuI_o
Although spray polyurethane foam has many advantages over other types of insulation, spray foam installation isn’t foolproof. Some builders have reported problems with sloppy foam insulation. For example, some installers have been known to begin spraying before the chemical components are up to temperature, which can affect component mixing and foam performance. When components are poorly mixed, or mixed in the wrong ratio or at the wrong temperature, cured foam has been known to shrink away from rafters or studs, leaving cracks. Some installers rush through their spraying, resulting in voids.
I employed a company to insulate my three story house in 2011. They started Insulating it in August of 2011...They said it would be a 3-4 day job. They installed it in 0.5"-8" lifts all in the same cavity, this left burned insulation and voids. They removed what they told me was the bad insulation and in the process cut many electrical wires. They fixed this. They then reinstalled too thick again in some spots and removed again. They then installed it for a 3rd time. The areas that I thought were good are now separating from the structural members leaving voids. As of October 2012, 1 year and 2 months of dealing with the contractor I told them I want proof that what has been installed carries a warranty or I want my money back and I will fix the problems myself. They have yet to provide me with this warranty. I have spent many hours in the house looking at what is bad and they need to fix. I am frustrated, 14 months of additional rent due to their negligence. I would like to know how I can get proof that the product carries the manufacturers lifetime warranty, or has it been installed improperly throughout the entire house. Desperately awaiting your response. 
With constant exposure to heat, cold, UV radiation, rain, snow, hail, high winds and possible mechanical damage, a roof can be the most vulnerable component of a building’s exterior. However, a roof’s long-term performance can be enhanced — and major roofing problems avoided — with correct design, quality materials, proper installation and workmanship, and comprehensive care.
When it comes to weatherproofing your RV roof, the Flex Seal liquid roof is one of those we’re proud to recommend because it can be applied in all temperatures. It can also protect your camper roof from even the harshest weathers, including rain, snow and wind. With it, you can keep your roof protected from changing temperatures, eventually prolonging its lifespan.
You've got no argument from me there, Dennis. Getting a good installer if you're going with spray foam is crucial. Many builders or homeowners don't know how to find one, however, and that's where third party inspections come in. Also, even good installers have bad days, but if someone comes in behind them with a measuring probe and a Blower Door, there will be fewer sub-par foam jobs.  
In the early days of insulating attics, people believed the insulation was a heat source. That’s not the case, as the insulation is actually a barrier between two areas of different temperatures. As for the “hot roof” theory, the unvented attic system could make the temperature of the roof go up a little, but this increase won’t cause damage to your shingles. https://youtube.com/watch?feature=player_embedded&v=ggLAUsiuI_o

Spray foam is available in two different types: open-cell spray foam which is usually $0.44 to $0.65 per board foot and closed-cell spray foam which is about $1 to $1.50 per board foot. The average cost to have spray foam professionally installed is about $2,316. This number can vary depending on whether the home being insulated is newly constructed. However, finished homes are not a good candidate for spray foam insulation but great for weatherization or an energy audit.   https://youtube.com/embed/ggLAUsiuI_o

Sta-Kool 780 Siliconized Acrylic White Elastomeric Roof Coating Sta-Kool 780 Siliconized Acrylic White Elastomeric Roof Coating is a high quality flexible white acrylic roof coating. Product is enhanced with silicone for improved water resistance adhesion and life expectancy. Product resists cracking peeling while offering tremendous durability and long term life. The coating forms a durable protective barrier which ...  More + Product Details Close https://www.youtube.com/attribution_link?a=ggLAUsiuI_o&u=watch?v=XXXXXX&feature=share
There are several types of reflective roof coatings that impart varied reflectance rates/ values. Typically, the reflective coatings are what are commonly referred to as white coatings and there are also aluminum coatings typically used with asphalt. Highly reflective white roof coatings are typically comprised of acrylics, urethanes, silicones, SBS, SEBS, and other types.

Spray Foam Metal Building


Closed-cell (aka two-pound foam) is denser than open-cell at about 2 pounds per cubic foot. Its R-Value is between 6-6.5 per inch. As a result, this kind of foam is much more expensive than its counterpart. The reason closed-cell doesn't need a vapor retarder is because it already has one. It's permeance is 0.8 perm, which means it can handle cold climates without the use of an additional board or drywall. Closed-cell uses hydroflurocarbons (HFCs) as part of its makeup. However, this material has been known to have a high global warming effect. If you want a green insulation solution, this is not the material to use. A way to avoid this and still use closed-cell is by installing it alongside fiberglass batts.
NOVA Spray foam did just as they promised and, more importantly, for the price they quoted. The two employees who ultimately installed the product were very nice, pleasant, and respectful. Bottom line: We are delighted with the install. Our house now holds a more stable temperature and no longer has hot spots. It used to be very difficult to cool our upstairs bedrooms; those days are gone! Pocketbook issues: For the last three billing cycles we have used approximately one third less electricity as the AC does not come on as often. Would we do this again? Yup! Do we recommend this installer? Yup! Do the neighbors think it’s cool? Yup!
This is in great contrast to my friend's experience. Her attic spaces were sprayed and the foam is actually pretty, and I was in her attic 6-7 days after it was sprayed and could hardly smell anything when I stuck my face up to the foam. And she did not have to clean up one speck of dust during or after the spraying. I got the name/number of the guy from her who managed her attic project, but between the time he did my house and the time he did her house, he was let go from the company who did her attic and hired by another company. He assured me everything would be the same, etc., etc., and I had no reason to believe anything had changed, but the sprayers who did my house later admitted they had never sprayed an attic before and I also found out that the foam used in my attic was from a different manufacturer. Neither my friend nor I had any idea this guy was with different company then, until the week after they filled my attic with off ratio foam, and my home with toxic vapors.   http://www.youtube.com/watch?v=ggLAUsiuI_o&feature=youtube_gdata
Installing spray foam is easy to do and can dramatically improve a building or home’s energy efficiency and thermal resistance. Our closed cell foam is so efficient just 3 inches of foam appled inside of wall cavities provides an insulation value of over R18!. Our products are specially formulated for both new construction and existing homes and buildings.
Global warming potential (GWP), as defined by the EPA, is a measure of how much energy the emissions of 1 ton of a gas will absorb over a given period of time, relative to the emissions of 1 ton of carbon dioxide (CO2).  Spray foam insulation products that use water as the blowing agent - typically open-cell foam however Icynene’s ProSeal Eco is a 100 percent water blown closed-cell spray foam – have a global warming potential of 1, the lowest possible number.  This is because water in the mixture reacts during the application process to release carbon dioxide and heat. The GWP of the blowing agent is that of carbon dioxide. Carbon dioxide has a GWP of 1.
As this example illustrates, it's important to seal the envelope completely. One of spray foam's biggest selling points is its air-sealing ability, but it can't seal places where it's not sprayed. One of the nice things about using spray foam in new construction is that you can do a Blower Door test before the drywall goes in. Even better, you can test for leaks with a fog machine.
Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed. 

Spray Foam Under House


The RV roof coating is a sealing, weatherproofing and waterproofing product that is used in recreational vehicles, campers and trailers, to name some. It works effectively in sealing the roof’s membrane from water and moisture that would otherwise build up and cause damage to the roof. When unattended, the buildup can eventually leads to leaks inside the RV, causing so much discomfort to your loved ones.
Although spray polyurethane foam has many advantages over other types of insulation, spray foam installation isn’t foolproof. Some builders have reported problems with sloppy foam insulation. For example, some installers have been known to begin spraying before the chemical components are up to temperature, which can affect component mixing and foam performance. When components are poorly mixed, or mixed in the wrong ratio or at the wrong temperature, cured foam has been known to shrink away from rafters or studs, leaving cracks. Some installers rush through their spraying, resulting in voids.
For large jobs, professionals such as Dr. Energy Saver use two-part foam, which comes in larger containers. With 2-part spray foam, it's necessary to mix separate resin and catalyst compounds at the application nozzle. Combining these ingredients starts a chemical reaction that creates expanding foam. Contractors use small 2-part foam "kits" to air-seal an attic or to seal and insulate ductwork. To insulate an entire attic or wood-framed wall with spray foam, the resin and catalyst compounds are pumped to the application nozzle from 50-gallon drums in a specially equipped truck.

How Much Is Spray Foam Per Sq Ft

×