The guys who sprayed my attic were trained and certified, but I later found out, too late, that they had no experience and my attic was the first they'd ever sprayed. I was also never told to vacate my house for any length of time, and so I (and my pets) were in the house the day they sprayed and the entire time the off ratio foam was filling my home with horrendous vapors. The company kept telling me that it was a good job and I had nothing to worry about, even after I'd had 2 other experienced sprayers from 2 different companies visually examine the foam and confirm that large areas appeared to be off ratio. The 3rd sprayer from yet another company, was also outraged because the company who did my attic had failed to vacuum up all of the old cellulose insulation, and he also noticed areas where the foam was shrinking or pulling away, and this was not even 5 weeks after the spraying.  
I live in Baton Rouge LA with a very old and drafty house. There is no blockages in the walls between the crawl space and attic. Lots of critters just come on in. I would like to used closed cell sprayed under house to warm up floors and block moisture. I would like to spray closed cell into attic, but am afraid of enclosing attic due to moisture build-up. Can I spray closed cell against the attic floor in same way as installing bats, thus leaving my venting the same as it always has been. Other ideas? Thanks.

Spray Foam Roof Insulation


We live in middle TN and had our house foamed last year. We noticed recently that some of the foam was shrinking and seperating from the floor joists. We contacted the installer and he informed us that the manufacturer had a problem with a batch of foam during the time frame we had our house sprayed. The contractor wasn't sure if we had the recalled batch installed in our house or not. He said he would check the batch numbers and let us know. He seems like a nice guy promising to do whatever it takes to fix any problems. Do we trust him, however, to be truthful about the batch number? Do we have any options for finding out the information ourselves? I inspected the entire crawl space of the house and noticed approximately (5) areas that were seperating and a couple areas where the foam didn't adhere to the block. Do I assume by it being so infrequent that it is nothing to be concerned about? My concern is the walls that are not capable of being visually inspected because of sheetrock.
Loctite tite foam is a new generation of Loctite tite foam is a new generation of polyurethane-based insulating foam sealant that expands to fill seal and insulate gaps and cracks inside or out. It is white polymer foam based on purified and concentrated ingredients that provides 4 times more density versus conventional foams for better durability and insulation. ...  More + Product Details Close
In general, cantilevered steel beams are a nightmare. If part of the steel beam is in contact with exterior temperatures, then it's best if the interior portion of the steel beam is covered on all sides with insulation. This is generally impossible (because the interior portion of the cantilevered beam generally supports a load, meaning that you can't wrap the steel beam in insulation on all sides).
Spray foam insulation helps lower utility costs because it blocks heat and cold from the outdoors. Recent studies by the U.S. Department of Energy state that around 40 percent of all energy is lost through poor insulation. Spray foam insulation is able to insulate homes at least 50 percent more than traditional insulation products. Spray foam insulation can also provide protection against moisture, which otherwise leads to the unwanted development of mold and mildew. And it can also be used for noise reduction as well. In fact, spray foam is good for homes and buildings in which outdoor noise can be a distraction.
The problem was that the installer was doing his first spray foam job ever, and the thickness of the insulation varied from zero (visible roof deck) to about 9". Unfortunately, good average thickness doesn't cut it. The coverage needs to be uniform because a lot of heat will go through the under-insulated areas. (See my article on flat or lumpy insulation performance.)
This tropic heat actually is the cause that the steel structure, which most roofs in that part of the world are built on, expands and contracts all the time. By doing so, the sun-battered steel structure causes the roof tiles to dislodge and slowly creates small openings between the roof tiles, through which rain water can run into, creating leaks that can cause much damage to plastered ceilings and electric wiring.
Spray foam is a chemical product created by two materials, isocyanate and polyol resin, which react when mixed with each other and expand up to 30-60 times its liquid volume after it is sprayed in place. This expansion makes it useful as a specialty packing material which forms to the shape of the product being packaged and produces a high thermal insulating value with virtually no air infiltration. 

How Much For Spray Foam Roof


I just received this and it worked well for me. It works well for small gaps (around windows, between studs), but probably not the right tool for larger gaps (>1" or 2"). If used in larger gaps, it works OK if it is layered in. Spray a little and wait for it to set, then layer another on top, etc... This is pretty much noted by the seller. It is pretty much exactly as described and priced right, so 5 stars. If you need to do larger gaps, buy 2 part. http://youtube.com/v/ggLAUsiuI_o
Sealection 500 is a cutting-edge formula of open-cell spray foam insulation, which expands 120 times its liquid volume to insulate and seal all cracks, gaps, and joints with a single application, and is easy to install and finish. It has dramatically increased energy efficiency for millions of residential and commercial property owners. This translates to a high-performing product for builders, shorter application, and finishing times for contractors, and lower energy bills for homeowners and commercial building owners.

Where Can I Buy Closed Cell Spray Foam

×