You've got no argument from me there, Dennis. Getting a good installer if you're going with spray foam is crucial. Many builders or homeowners don't know how to find one, however, and that's where third party inspections come in. Also, even good installers have bad days, but if someone comes in behind them with a measuring probe and a Blower Door, there will be fewer sub-par foam jobs.  
Spray foam insulation helps lower utility costs because it blocks heat and cold from the outdoors. Recent studies by the U.S. Department of Energy state that around 40 percent of all energy is lost through poor insulation. Spray foam insulation is able to insulate homes at least 50 percent more than traditional insulation products. Spray foam insulation can also provide protection against moisture, which otherwise leads to the unwanted development of mold and mildew. And it can also be used for noise reduction as well. In fact, spray foam is good for homes and buildings in which outdoor noise can be a distraction.
When it comes to insulating the house, fiberglass tends to be the common form of insulation. However, after comparing fiberglass and spray foam insulation, it’s shocking how fiberglass tends to be the lesser of the two. Although it has deemed reliable over the years, there are way more benefits to insulating your home with spray foam. One of those benefits includes regulating the temperature of your house.

a) Make sure that your house has been well heated prior to installation because the foam expands at different rates as it hits surfaces with different temperatures. If it is cold outside the sheathing may be much colder than the studs consequently the foam may expand more from the sides of the wall cavity creating air pockets in the wall cavity. This can be minimized by an experienced installer.
Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed.
Q. "I talked to a building product supplier for WALLTITE spray foam, he is suggesting to use 2" or 3" of closed cell-spray foam in the joists areas instead of the batts insulation. He says it will work with outboard rigid insulation. There is a location of a cantilevered floor area with steel beam so I may need to use spray foam to protect the steel beam. It would then be convenient continue to spray in the floor joist cavities and then apply 5" of polyiso outboard of the bottom cantilever floor sheathing."
To avoid the expense re-roofing a house that is simply suffering from nail fatigue, and to obtain optimum insulation, an 85mm layer of polyurethane foam can be sprayed onto the underside of the slates or tiles of a pitched roof. This stabilises and weatherproofs the roof by fixing the nails, battens and roofing felt. As the foam is a superior insulant, coupled with just 100mm of insulation at joist level, your roof will also meet the stringent thermal performance standards required for a new home. A typical roof can be insulated using the polyurethane treatment for around half the cost of re-roofing.
I am an Architect in Toronto. I am designing a new roof addition to a row house building. Because of existing conditions and the shape of the new roof. It may be easiest to use closed cell spray foam within the areas of the joists. My question is when spray foam is used in this situation do I need to worry about how the joist members may be thermal bridges? It is not common to provide a little bit of rigid insulation to protect the joist members? The additional layer of outboard insulation will require an extra layer of plywood above the insulation which will add to cost.
They’re the more expensive option than the first one we have discussed above, but they also offer top benefits for the RV owners who want to repair or maintain their RV roof and protect it from UV rays and harsh weather elements. Based on many reviews, these types can offer more durability than the silicone and acrylic types. They can also offer an excellent impact resistance from twigs, leaves and other outer elements.

Spray Foam Exterior Walls


Typical roof coating dry film thickness vary from paint film thickness (plus or minus 3 dry mils) to more than 40 dry mils. This means a roof coating actually becomes the top layer of a composite roof membrane and underlying system. As such, the roof coating is the topmost layer of protection for the membrane, receiving the impact of sunlight (both infrared and ultraviolet (UV), rain, hail and physical damage. http://www.youtube.com/v/ggLAUsiuI_o&feature=youtube_gdata

Warning: EnergyGuard™ Elastomeric Roof Coatings can freeze below 32° F. This is because the product is water based. In case of freezing temperatures, stop the application process. After application, you must allow the product time to dry before exposing the elastomeric roof coating to foot traffic or water. You should also cover the containers and dispose them responsibly after application. In case you or someone else i.e. a child ingests the coating seek immediate medical attention. Don't induce vomiting.


Warning: EnergyGuard™ Elastomeric Roof Coatings can freeze below 32° F. This is because the product is water based. In case of freezing temperatures, stop the application process. After application, you must allow the product time to dry before exposing the elastomeric roof coating to foot traffic or water. You should also cover the containers and dispose them responsibly after application. In case you or someone else i.e. a child ingests the coating seek immediate medical attention. Don't induce vomiting. 

You've got no argument from me there, Dennis. Getting a good installer if you're going with spray foam is crucial. Many builders or homeowners don't know how to find one, however, and that's where third party inspections come in. Also, even good installers have bad days, but if someone comes in behind them with a measuring probe and a Blower Door, there will be fewer sub-par foam jobs.   http://m.www.youtube.com/embed/ggLAUsiuI_o
Q. "I talked to a building product supplier for WALLTITE spray foam, he is suggesting to use 2" or 3" of closed cell-spray foam in the joists areas instead of the batts insulation. He says it will work with outboard rigid insulation. There is a location of a cantilevered floor area with steel beam so I may need to use spray foam to protect the steel beam. It would then be convenient continue to spray in the floor joist cavities and then apply 5" of polyiso outboard of the bottom cantilever floor sheathing." http://www.youtube.com/watch?feature=youtube_gdata&v=ggLAUsiuI_o
Excellent kit for insulating a house. Slow rising foam takes longer to insulate an area as you must do it in layers 1" thick. Any thicker can overheat the chemicals and prevent a proper cure and off-gassing. Recommend purchasing a second suit and nozzles so you can use it multiple days to achieve the thickness desired for the highest R value. Seals up and insulates much better than traditional fiberglass. The sound suppression is noticeably different. Used it to insulate the ceiling above our bedroom. The sound is remarkably more quiet than the fiberglass insulation we had before. The only down side is the weight of the containers. Using a smaller kit would be easier to handle and move around when spraying a ceiling in an attic. A word of caution, use plywood that spans at least 2 joist per container when spraying in an attic to hold the weight.
Today’s “third generation” of blowing agents have a GWP of 700 to 1000 which is still remarkably high considering water/CO2 has a GWP of 1. However, innovation from some chemical manufacturers like the Chemours Company have introduced the next generation of HFO blowing agents such as Opteon 1100, which significantly reduces the GWP impact when using closed-cell spray foam insulation products.
Q. "I talked to a building product supplier for WALLTITE spray foam, he is suggesting to use 2" or 3" of closed cell-spray foam in the joists areas instead of the batts insulation. He says it will work with outboard rigid insulation. There is a location of a cantilevered floor area with steel beam so I may need to use spray foam to protect the steel beam. It would then be convenient continue to spray in the floor joist cavities and then apply 5" of polyiso outboard of the bottom cantilever floor sheathing."

How Much Is Spray Foam Insulation A Square Foot


Today’s “third generation” of blowing agents have a GWP of 700 to 1000 which is still remarkably high considering water/CO2 has a GWP of 1. However, innovation from some chemical manufacturers like the Chemours Company have introduced the next generation of HFO blowing agents such as Opteon 1100, which significantly reduces the GWP impact when using closed-cell spray foam insulation products.
One thing I wanted to mention was that I think your price point is a little high and that might deter people from considering spray foam. As a project manager for a spray foam company for years I can tell you that we offer 0.5 Lb. open-cell foam at around $.25/board foot. We even offer a 1.0 Lb. open-cell foam for less/the same cost as you quoted the 0.5 Lb. foam for above. The 1/0 Lb. open-cell foam has an R-value of almost 5.
You are eligible for a full refund if no ShippingPass-eligible orders have been placed. You cannot receive a refund if you have placed a ShippingPass-eligible order. In this case, the Customer Care team will remove your account from auto-renewal to ensure you are not charged for an additional year and you can continue to use the subscription until the end of your subscription term.
Warning: EnergyGuard™ Elastomeric Roof Coatings can freeze below 32° F. This is because the product is water based. In case of freezing temperatures, stop the application process. After application, you must allow the product time to dry before exposing the elastomeric roof coating to foot traffic or water. You should also cover the containers and dispose them responsibly after application. In case you or someone else i.e. a child ingests the coating seek immediate medical attention. Don't induce vomiting.
Global warming potential (GWP), as defined by the EPA, is a measure of how much energy the emissions of 1 ton of a gas will absorb over a given period of time, relative to the emissions of 1 ton of carbon dioxide (CO2).  Spray foam insulation products that use water as the blowing agent - typically open-cell foam however Icynene’s ProSeal Eco is a 100 percent water blown closed-cell spray foam – have a global warming potential of 1, the lowest possible number.  This is because water in the mixture reacts during the application process to release carbon dioxide and heat. The GWP of the blowing agent is that of carbon dioxide. Carbon dioxide has a GWP of 1.
Porch urns are an excellent way to add seasonal curbside flair. However, tall items such as twigs, birch stems or even pumpkins can sway in the breeze and make a mess of your carefully planned decor. To prevent things from shifting, place your items in the container and spray around them with expanding foam to create a comfy nest that will keep your urns looking great. Place a layer of moss, hay or greenery on top to finish the look.
That’s $58.3 Billion dollars. That’s roughly how much money we wasted in 2010 in the US according to the Department of Energy because of air leaking out of our building envelopes. If your building leaks energy, you’re paying more for energy than you need to. Clearly you’re not alone. If you’re ready to claim your share of the savings, it’s quicker and easier than you think.

Spray Foam Insulation


Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed.

Spray Foam Under House


Sta-Kool 780 Siliconized Acrylic White Elastomeric Roof Coating Sta-Kool 780 Siliconized Acrylic White Elastomeric Roof Coating is a high quality flexible white acrylic roof coating. Product is enhanced with silicone for improved water resistance adhesion and life expectancy. Product resists cracking peeling while offering tremendous durability and long term life. The coating forms a durable protective barrier which ...  More + Product Details Close https://www.youtube.com/watch?v=ggLAUsiuI_o&feature=share
FROTH-PAK Foam Sealant is a two-component quick-cure polyurethane FROTH-PAK Foam Sealant is a two-component quick-cure polyurethane foam that fills cavities penetrations cracks and expansion joints. FROTH-PAK foam sealant can also be used as a sealant and void fill in many roofing applications. FROTH-PAK is chemically cured foam which significantly reduces curing time. FROTH-PAK dispenses expands and becomes tack ...  More + Product Details Close
I don't even want to ask this question but... several years ago we hired a local contractor to spray high density foam on the roof deck and walls of our unfinished 2nd floor. We realized that the job was done poorly and cut an access into the attic space to assess things. We realize now that they spray foamed directly to the chimney (no flashing). The chimney is currently used for a woodstove and DHW venting. The DHW will go away but wood stove will remain. My question is, how bad (unsafe) is this? I have found information on foam exposure to fire but have not been able to find anything about temperature ratings in general (i.e. what happens on prolonged exposure to high temperatures).

They’re the more expensive option than the first one we have discussed above, but they also offer top benefits for the RV owners who want to repair or maintain their RV roof and protect it from UV rays and harsh weather elements. Based on many reviews, these types can offer more durability than the silicone and acrylic types. They can also offer an excellent impact resistance from twigs, leaves and other outer elements.
Before you decide on spray foam or another method of insulation, it's important to understand the superiority of spray foam compared to traditional materials. When compared to fiberglass batts, spray foam offers nearly double the R-value per inch, achieves air-sealing and insulation in one step, won't be damaged by mold or moisture, and won't settle, compress, or otherwise be damaged to the point it needs replacement.

Q. "I talked to a building product supplier for WALLTITE spray foam, he is suggesting to use 2" or 3" of closed cell-spray foam in the joists areas instead of the batts insulation. He says it will work with outboard rigid insulation. There is a location of a cantilevered floor area with steel beam so I may need to use spray foam to protect the steel beam. It would then be convenient continue to spray in the floor joist cavities and then apply 5" of polyiso outboard of the bottom cantilever floor sheathing." http://www.youtube.com/watch?feature=youtube_gdata&v=ggLAUsiuI_o

I am building a house in Central Texas (Caldwell). Several builders are cautious about using foam insulation and/or a closed attic. I would like to use both. Here in Texas, heat and humidity (except for the past few years of drought) are a continuing problem. Which type of foam would be the best to use in our home, where should the vapor barrier be or should be use one at all, if we are using fans in the exterior walls to supply fresh air to the house, do we need a vented attic or will it cause more problems than it solve? I have printed out your article and the blogs to give to my contractors and architect, but I would really appreciate your comments on the products being used in my part of the US. 
A: The RV roof coating works by waterproofing, weatherproofing and sealing our RV roofs from elements, including rain, snow, wind and other outer forces. It can also resist impact from leaves, twigs, dusts and other things that would otherwise damage the roof. It also works by reflecting UV rays, keeping the roof from degradation. The roof coating can also prevent leaks, heating and cooling loss and discomfort in our RV.
There is a significant price difference when it comes to using foam insulation to insulate a new versus older home. Spraying insulation inside a newly constructed home is easier because the installation company can ensure the insulation will work effectively and design it for optimum defense against sound, heat transfer and utility costs. Installing spray foam in older homes that contain existing insulation can cost additional time and money -- it is not usually recommended as compared to weatherization or an energy aduit. https://www.youtube.com/v/ggLAUsiuI_o&feature=kp
“It’s been scientifically proven that the temp of the shingles rises only a couple of degrees when there is an unvented attic compared to a vented attic,” said Garry Barlow, estimator at RetroFoam of Michigan. “If we lived in a southern state it has been proven that the longevity of the shingle did diminish by only one year. In the northern states there was no difference in the life span of the shingles.” http://www.youtube.com/v/ggLAUsiuI_o
When it comes to weatherproofing your RV roof, the Flex Seal liquid roof is one of those we’re proud to recommend because it can be applied in all temperatures. It can also protect your camper roof from even the harshest weathers, including rain, snow and wind. With it, you can keep your roof protected from changing temperatures, eventually prolonging its lifespan. https://youtube.com/watch?feature=youtube_gdata&v=ggLAUsiuI_o

This high R-value of 4.45 at 1 inch, polyurethane insulation expands to seal cracks, gaps, and voids in attics, walls, crawl spaces, and ceilings. Agribalance is a three-quarter pound density foam that reduces air leakage by improving energy efficiency, and reducing moisture intrusion and outside contaminants such as dust, dirt, and allergens. As a result, builders can generally install smaller, more energy-efficient HVAC systems and achieve similar, or superior comfort compared to traditionally insulated structures which require a larger, less efficient HVAC system – resulting in higher energy costs.
once the foam is installed correctly, it is a inert plastic not much different than the foam cushions you sit on. there is not a health rick unless you have off ratio uncured foam that has not mixed properly. the foam is absolutely a health risk in its raw forms before it is mixed and cured. You should not be in the building without proper respirators and eye protection. The spray foam industry should be controlled and regulated by the same standards, testing and inspections that framing ,electrical and plumbing are. until that happens then you will have idiots with spray rigs ruining peoples homes and ruining the market for honest foam contractors that know how to price a job fairly and complete it correctly.

How Much Is Open Cell Spray Foam Insulation

×