Spray foam comes in two flavors, open cell and closed cell, and provides both parts of the building envelope - the insulation and the air barrier. The building envelope should completely surround the conditioned space, and the insulation needs to be in contact with the air barrier. Since spray foam is both insulation and air barrier, proper alignment of insulation and air barrier is guaranteed.
RetroFoam of Michigan has more than 15 years of experience insulating thousands of homes and pole barns across the lower peninsula. We hear a lot of misconceptions about foam insulation and work to make sure we clear up any wrong ideas about foam insulation. Our staff helped us put together this list of misconceptions adding their insights to dispel any misinformation.
Spray polyurethane foam, or SPF, is the main type of 2-part, closed-cell spray foam used by insulation contractors. Large-scale insulation jobs require special equipment as well as safety gear to protect the installer from chemical fumes during installation. When the foam cures and hardens just several minutes after application, it's completely safe for as long as it stays in place.
In the case you have above the installer wasn't reading his foam. They must be trained to do that as they spray. Temps and conditions are constantly changing thru out the day. Either he wasn't properly trained or if he was,he wasn't doing his job! This is a serious problem with people jumping in to the foam business. A lot of homeowners and builders are looking the best price and end up with someone who doesn't know what they are doing. Hope this info helps. Foam insulation is a great product. It just has to be done right by someone who knows what they are doing.

Spray Foam Sealant


Light-density open-cell SPF is commonly known as half-pound foam. It is a semi-rigid material with a sponge-like appearance that expands during installation and creates small, open cells that are filled with carbon dioxide. Due to its ability to expand during the application process, it fills cracks, crevices and voids and adheres to irregular surfaces or substrates to form an air sealing insulation.[12]

Repair and seal roof penetrations, tears, open seams, etc. using Elastek 103 Crack & Joint Sealant and reinforce with polyester roof fabric as necessary. In larger or deep ponding areas, apply Elastek 500 Puddle Plaster to fill in areas that hold water. Avoid using plastic roof cement. Serious ponding should be referred to a roofing contractor. Blisters in previous coatings may be opened but these areas must be allowed to dry-out completely. Blisters in the roofing ply should be left alone unless likely to break. Caulk and reinforce open seams, roof penetrations, cracks, and tears. These are potential leak points so work carefully and thoroughly. Use fabric to build flashings around roof edges or roof penetrations, and to reinforce various coating repairs. A polyester fabric is used because it will stretch with the coatings. (Fiberglas fabric is not recommended.) Fabric is normally cut to extend three inches beyond the repaired area in all directions. The coating is applied to the roof surface and the fabric is immediately pushed into the wet surface. An additional coat is applied over the fabric and the patch is allowed to dry. If your roof has stucco parapets, examine them for cracks along the sides and top. These areas often permit water to enter the wall and can cause blisters and wrinkles in the roof surface. Repair with Elastek 103 Crack & Joint Sealant. If you do not have parapets, examine the metal drip edge for a tight seal with the roof membrane. Use 4″ or 6″ roofing fabric covered under and over with Crack & Joint Sealant to seal cracks along drip edges, penetrations, and open seams.
Closed-cell (aka two-pound foam) is denser than open-cell at about 2 pounds per cubic foot. Its R-Value is between 6-6.5 per inch. As a result, this kind of foam is much more expensive than its counterpart. The reason closed-cell doesn't need a vapor retarder is because it already has one. It's permeance is 0.8 perm, which means it can handle cold climates without the use of an additional board or drywall. Closed-cell uses hydroflurocarbons (HFCs) as part of its makeup. However, this material has been known to have a high global warming effect. If you want a green insulation solution, this is not the material to use. A way to avoid this and still use closed-cell is by installing it alongside fiberglass batts. https://youtube.com/e/ggLAUsiuI_o?app=desktop
RetroFoam of Michigan has more than 15 years of experience insulating thousands of homes and pole barns across the lower peninsula. We hear a lot of misconceptions about foam insulation and work to make sure we clear up any wrong ideas about foam insulation. Our staff helped us put together this list of misconceptions adding their insights to dispel any misinformation.
c) Make sure that the over expanded access is properly removed from the walls. We had a junior cutter taking too much off by bending his saw into the cavity. Look closely at the inside wall corners, and ceiling/wall corners to make sure that the foam is properly removed flush with the studs. If it has not been cut back flush it may lead to uneven drywall finishes .
Henry 587 Dura-Brite White Elastomeric Roof Coating is Henry 587 Dura-Brite White Elastomeric Roof Coating is a premium high solids formula offering better weather protection solar reflectivity and longevity than economy grade reflective roof coatings. Cured coating forms a permeable membrane which prevents liquid infiltration but allows moisture vapor to vent or breathe out of underlying substrate. Recommended ...  More + Product Details Close 

The product is an acrylic coating, which is packed conveniently for ease of use. As it is also in one-gallon size, you can rely on its supreme area coverage reaching up to 125 square feet. The Dicor rubber roof coating is also very easy to apply. When shopping around for a roof coating, we believe it pays off to find an easy to apply product for fast results. It is one of the best qualities of the RV roof coating that makes it a top pick in the category. http://www.youtube.com/watch?feature=youtu.be&v=ggLAUsiuI_o
I am building a house in Central Texas (Caldwell). Several builders are cautious about using foam insulation and/or a closed attic. I would like to use both. Here in Texas, heat and humidity (except for the past few years of drought) are a continuing problem. Which type of foam would be the best to use in our home, where should the vapor barrier be or should be use one at all, if we are using fans in the exterior walls to supply fresh air to the house, do we need a vented attic or will it cause more problems than it solve? I have printed out your article and the blogs to give to my contractors and architect, but I would really appreciate your comments on the products being used in my part of the US. 

Please Note: Prices, promotions, styles and availability may vary by store and online. Inventory is sold and received continuously throughout the day; therefore, the quantity shown may not be available when you get to the store. This inventory may include a store display unit. Online orders and products purchased in-store qualify for rebate redemption. Mail-in Rebate is in the form of merchandise credit check, valid in-store only. Merchandise credit check is not valid towards purchases made on MENARDS.COM®. By submitting this rebate form, you agree to resolve any disputes related to rebate redemption by binding arbitration and you waive any right to file or participate in a class action. Terms and conditions available at www.rebateinternational.com®
This high R-value of 4.45 at 1 inch, polyurethane insulation expands to seal cracks, gaps, and voids in attics, walls, crawl spaces, and ceilings. Agribalance is a three-quarter pound density foam that reduces air leakage by improving energy efficiency, and reducing moisture intrusion and outside contaminants such as dust, dirt, and allergens. As a result, builders can generally install smaller, more energy-efficient HVAC systems and achieve similar, or superior comfort compared to traditionally insulated structures which require a larger, less efficient HVAC system – resulting in higher energy costs.
Steve: If your spray foam installer leaves the vents open, he will be committing the 2nd of the 4 problems I described above. You will most likely have comfort and efficiency problems. You may well have condensation problems. You will be spending a lot of money on a product that likely won't perform as it should. Don't let him leave the vents open. If the installer you've chosen doesn't understand this, you may want to choose someone else. 
Thank you, Allison. We have a split system unit (actually 5) with the heat being propane. The foam guy said that it needed ventilation, so completely sealing the attic wouldn't be a good idea. It sounds like you are saying that the systems need to be vented out of the attic or replaced with some type of closed system. But I shouldn't bother spraying if the plan is to leave the soffet vents open. Is that correct?
There are several types of reflective roof coatings that impart varied reflectance rates/ values. Typically, the reflective coatings are what are commonly referred to as white coatings and there are also aluminum coatings typically used with asphalt. Highly reflective white roof coatings are typically comprised of acrylics, urethanes, silicones, SBS, SEBS, and other types.

I started using Gaco years ago primarily to solve ponding water Problem. It has work well, solved my problems with other roofing options and repairs as well as many other Flat roof issues.  My only problems were experienced when I did not clean the surface well enough for good adhesion.  Follow the Instructions.  Great product and highly recommended. .
Excellent kit for insulating a house. Slow rising foam takes longer to insulate an area as you must do it in layers 1" thick. Any thicker can overheat the chemicals and prevent a proper cure and off-gassing. Recommend purchasing a second suit and nozzles so you can use it multiple days to achieve the thickness desired for the highest R value. Seals up and insulates much better than traditional fiberglass. The sound suppression is noticeably different. Used it to insulate the ceiling above our bedroom. The sound is remarkably more quiet than the fiberglass insulation we had before. The only down side is the weight of the containers. Using a smaller kit would be easier to handle and move around when spraying a ceiling in an attic. A word of caution, use plywood that spans at least 2 joist per container when spraying in an attic to hold the weight.

How Much Is Spray Foam Roofing


Roof coatings made with acrylics, urethanes or asphalt soften under the stress of ponding water or snowpack. Eventually, these roof coatings will bubble and peel away from the substrate, leaving your roof vulnerable to leaks, rot, and decay. However, GacoRoof’s 100% silicone formulation is designed to stand up to whatever the elements dish out. Silicone will withstand areas of ponding water without softening, bubbling or peeling from the substrate. Acrylic, urethane and asphalt roof coatings decompose and wear away from the stress of harsh sunlight, UV rays, and freeze-thaw cycles.

How Much To Spray Foam Crawl Space

×