Thank you, Allison. We have a split system unit (actually 5) with the heat being propane. The foam guy said that it needed ventilation, so completely sealing the attic wouldn't be a good idea. It sounds like you are saying that the systems need to be vented out of the attic or replaced with some type of closed system. But I shouldn't bother spraying if the plan is to leave the soffet vents open. Is that correct?
I have used the Froth-Pak 200 to air-seal rim joists--the area above the foundation wall in a basement. The first time I used it I did not shake the canisters well enough and the foam did not cure properly. Don't just shake the box for a few seconds. I take the tanks out of the box so I can shake/invert each tank for a minute or two. You will be able to hear the chemical sloshing around in the tanks. Also, don't ignore the recommended temperature for application--around 75 degrees F.

Where Can I Buy Spray Foam Insulation


Light-density open-cell SPF is commonly known as half-pound foam. It is a semi-rigid material with a sponge-like appearance that expands during installation and creates small, open cells that are filled with carbon dioxide. Due to its ability to expand during the application process, it fills cracks, crevices and voids and adheres to irregular surfaces or substrates to form an air sealing insulation.[12]

Spray Foam Insulation Near Me


“It’s been scientifically proven that the temp of the shingles rises only a couple of degrees when there is an unvented attic compared to a vented attic,” said Garry Barlow, estimator at RetroFoam of Michigan. “If we lived in a southern state it has been proven that the longevity of the shingle did diminish by only one year. In the northern states there was no difference in the life span of the shingles.”

I am building a house in Central Texas (Caldwell). Several builders are cautious about using foam insulation and/or a closed attic. I would like to use both. Here in Texas, heat and humidity (except for the past few years of drought) are a continuing problem. Which type of foam would be the best to use in our home, where should the vapor barrier be or should be use one at all, if we are using fans in the exterior walls to supply fresh air to the house, do we need a vented attic or will it cause more problems than it solve? I have printed out your article and the blogs to give to my contractors and architect, but I would really appreciate your comments on the products being used in my part of the US. 
Fort Worth, Arlington, Denton, Lewisville, North Richland Hills, Haltom City, Weatherford, Flower Mound, Keller, Grapevine, Bedford, Euless, Granbury, Hurst, Stephenville, Carrollton, Mineral Wells, Frisco, Azle, Crowley, Southlake, Rhome, Haslet, Aubrey, Colleyville, Dublin, Grand Prairie, The Colony, Dallas, Lake Dallas, Sanger, Kennedale, Little Elm, Roanoke, Decatur, Pilot Point, Mansfield, Poolville, Aledo, Argyle
Although spray polyurethane foam has many advantages over other types of insulation, spray foam installation isn’t foolproof. Some builders have reported problems with sloppy foam insulation. For example, some installers have been known to begin spraying before the chemical components are up to temperature, which can affect component mixing and foam performance. When components are poorly mixed, or mixed in the wrong ratio or at the wrong temperature, cured foam has been known to shrink away from rafters or studs, leaving cracks. Some installers rush through their spraying, resulting in voids.

Spray Foam Polyurethane


I was hesitant to buy this because many reviews stated that it didn't cover as advertised, but after reading/following all directions, everything turned out perfectly. It even seemed to apply slightly more than the 650 bd/ft that was advertised. The application process was very easy to learn and I applied all of the product in about 1 hour and 10 minutes- prep time included. I couldn't be happier and I purchased another kit this morning.

How Much Is Spray Foam Roof Insulation


The local foam installer that I used here in Hilton Head told me he looked for some peeling back of the foam. This was ensuring that it was at the perfect temperature which helped them maximize their yield (profit). I have open cell foam and it pulled away a little, and did so immediately (within minutes). They went back after they were done to any spots that pulled away too much and filled them with the touch up kit; they were looking for the top edge to roll just a little bit. 


Open-cell is also known as half-pound foam. It has an R-Value of 3.5-3.6 per inch, and its density is bout 0.5 pounds per cubic food. Low-density foams like these are made partially from raw biological materials Carbon dioxide or water is also used in the makeup. Open-cell uses far less material than closed-cell, but its R-Value is lower. Also, open cell requires a vapor retarder (like gypsum wallboard) and is riskier when used for roof sheathing. It's not highly recommended that you use open-cell insulation if you live in a cold climate unless you have that extra barrier. You should also compare how much money you spend versus how effective the open-cell insulation is wherever it's installed.
When choosing a waterproofing and sealing product, we must see to it that we can easily use and apply it using simple tools, including a squeegee or a paint roller. With ease of application, we can be certain that we can achieve hassle-free application and smoother and more attractive finish than other products could give. So when reviewing the products we have featured above, we have made sure that they are easy to apply.
“It’s been scientifically proven that the temp of the shingles rises only a couple of degrees when there is an unvented attic compared to a vented attic,” said Garry Barlow, estimator at RetroFoam of Michigan. “If we lived in a southern state it has been proven that the longevity of the shingle did diminish by only one year. In the northern states there was no difference in the life span of the shingles.” http://www.youtube.com/v/ggLAUsiuI_o
Note:  A board foot is defined as a 12" x 12" square at 1" thick. Actual output can be affected by a number of factors including temperature and humidity. The theoretical yield has become an industry standard for identifying certain sizes of two component kits. Theoretical yield calculations are performed in perfect laboratory conditions, without taking into account the loss of blowing agent or the variations in application methods and types.
Clean and free the roof surface of any debris and then dry the surface using a cloth. If you happen to have a current coating on the surface, check for adhesion. Consider removing loose coating, repairing, cleaning and then checking the area. Remember to use Energy Guard without thinning it because it is sold ready for use. Containers should not be left open except for a short period of time. You must also ensure that you check for any existing coating adhesion before opening Energy Guard. For application, you will require a brush preferably a bristle brush (synthetic) or a short nap roller. You can also use a good airless sprayer with a 0.031 or 0.027 tip to apply the coatings at (3000 psi/1gpm). You will also need water for cleaning up when you are done. https://youtube.com/watch?feature=youtu.be&v=ggLAUsiuI_o
Whether you’re sending something fragile in the mail or keeping valuables safe during a move, secure packing is everything. To protect a delicate item, simply fill a spare shopping bag half-full with spray insulation foam and place in the bottom of a box, pressing the item gently into the bag as it hardens to cushion the item. Repeat for the top and you have a DIY custom packaging solution that can handle the rigors of delivery.

We are turning our roof into an unvented roof assembly by raising the roof and blowing in SPF. We are planning to leave the existing vapor barrier down but remove the fiberglass batting and then adding 6" of SPF in all the cavities, to completely seal and insulate the house. Should we have any concerns about doing it "upside down" and not spraying the foam directly to the underside/sheathing of the roof? https://www.youtube.com/watch?v=ggLAUsiuI_o&app=mobile
As mentioned above, These coatings can work with almost any roof type. Another advantage is they are long-lasting. The coatings are resistant to fungi and mildew among other common materials that damage roofs with time. Another advantage of the coatings is that they are seamless, providing a neat uniform coating. Elastomeric coatings offer individual benefits to certain roof types. For instance, polyurethane foam roofing benefits greatly from the coatings by getting great ozone and UV light protection. The heat reflexive properties also offer great benefits such as lowering cooling costs. This advantage is enjoyed regardless of the rooftype. The heat reflexive properties also offer anti-aging properties when coatings reflect harsh sun rays which age roofs with time. Elastomeric roof coatings are also simple to use, VOC compliant and nontoxic.
Thoroughly clean the roof surface. Roofs collect oils from asphalt, chimneys, and cars plus lots of dirt and dust. Coatings don’t stick well to any of these. We recommend cleaning with an inexpensive solution of TSP or TSP Substitute in a bucket of water (follow label instructions). Use a broom to scrub ponding areas and areas of peeling coatings. Work a section at a time and hose off the dirty water. Sweep away puddles to promote drying. Do not allow wash water to dry on walls, furniture, windows, and visible surfaces. 
The problem was that the installer was doing his first spray foam job ever, and the thickness of the insulation varied from zero (visible roof deck) to about 9". Unfortunately, good average thickness doesn't cut it. The coverage needs to be uniform because a lot of heat will go through the under-insulated areas. (See my article on flat or lumpy insulation performance.)
Fill and seal expanding foam sealant is urethane Fill and seal expanding foam sealant is urethane foam designed to fill large areas quickly and permanently. Uses include filling holes cracks or gaps that require a complete airtight and waterproof seal but are too large to be filled with ordinary caulk. The foam expands approximately 3 times its original ...  More + Product Details Close
Find spray foam contractors, suppliers, equipment, news, and technical information about spray foam insulation, foam roofing, and protective coatings. If you are a homeowner, builder/architect, or interested to get into the spray foam business, we have set-up special areas just for you. Check out our information packed Spray Foam Guides to learn more. http://youtube.com/embed/ggLAUsiuI_o
Silicone coatings are typically produced by adding a catalyst and solvents to a silicone base. Because the silicone is a natural material, these coatings are bio-degradable. They can be applied to a roofing system using many different techniques, including spraying or rolling. Silicone coatings are available in many colors, including reflective white and translucent.
I don't know if it's common or uncommon, but installing a layer of rigid foam above your roof sheathing in order to interrupt thermal bridging is always a good idea, and is preferable in all respects to a roof assembly without any rigid foam above the sheathing. If you decide to install rigid foam above the roof sheathing, you shouldn't use closed-cell spray foam under the sheathing; either use open-cell spray foam (which is vapor-permeable) or a fluffy insulation like cellulose, mineral wool, or fiberglass (any of which will allow the roof sheathing to dry to the interior).
Polyurethane is a closed-cell foam insulation material that initially contains a low-conductivity gas in its cells.[5] As a result of the high thermal resistance of the gas, spray polyurethane insulation typically has an initial R-value around R-3.4 to R-6.7 per inch.[5] In comparison, blown fiberglass typically has an R-Value of only R-3 to R-4 per inch.[6]
This stuff works GREAT ! I live in an older mobile home that had a lot of leaks when I moved-in. I worked for two years to locate and fix them all. Now I simply go over all of the repaired places once a year just to be sure everything is OK. NO LEAKS FOR 4 YEARS NOW!!  Others here use "sno proof" or something that does not stop leaks. When I tell them about my success, they don't seem to want to pay the$ for this superior product. Too bad!. I used the tape in  repairing the leaks.

Light-density open-cell SPF is commonly known as half-pound foam. It is a semi-rigid material with a sponge-like appearance that expands during installation and creates small, open cells that are filled with carbon dioxide. Due to its ability to expand during the application process, it fills cracks, crevices and voids and adheres to irregular surfaces or substrates to form an air sealing insulation.[12]

Spray Foam Insulation Near Me


NOVA Spray foam did just as they promised and, more importantly, for the price they quoted. The two employees who ultimately installed the product were very nice, pleasant, and respectful. Bottom line: We are delighted with the install. Our house now holds a more stable temperature and no longer has hot spots. It used to be very difficult to cool our upstairs bedrooms; those days are gone! Pocketbook issues: For the last three billing cycles we have used approximately one third less electricity as the AC does not come on as often. Would we do this again? Yup! Do we recommend this installer? Yup! Do the neighbors think it’s cool? Yup!

How Much Does Spray Foam Insulation Cost

×