When choosing a waterproofing and sealing product, we must see to it that we can easily use and apply it using simple tools, including a squeegee or a paint roller. With ease of application, we can be certain that we can achieve hassle-free application and smoother and more attractive finish than other products could give. So when reviewing the products we have featured above, we have made sure that they are easy to apply. https://www.youtube.com/e/ggLAUsiuI_o
Sean, thanks for jumping in and answering John's questions. About choosing the right foam, I intentionally avoided the open cell vs. closed cell foam debate. I did this partly because it's worthy of an article all by itself, but mainly I didn't include it because, despite all the warnings the two sides issue about the other, I've never personally seen a problem caused by using open cell where they should've used closed cell or vice versa. I'm sure things like that happen; I just haven't seen it yet. http://www.youtube.com/watch?feature=youtube.be&v=ggLAUsiuI_o
once the foam is installed correctly, it is a inert plastic not much different than the foam cushions you sit on. there is not a health rick unless you have off ratio uncured foam that has not mixed properly. the foam is absolutely a health risk in its raw forms before it is mixed and cured. You should not be in the building without proper respirators and eye protection. The spray foam industry should be controlled and regulated by the same standards, testing and inspections that framing ,electrical and plumbing are. until that happens then you will have idiots with spray rigs ruining peoples homes and ruining the market for honest foam contractors that know how to price a job fairly and complete it correctly.
Amanda previously has worked as a breaking news and crime reporter, TV news producer, and editor in Flint and Detroit. Throughout her career as a journalist, she has won several awards from the Detroit Chapter of Society of Professional Journalists and the Michigan Press Association. As part of the RetroFoam of Michigan family, Amanda uses her experience as a journalist to write content that will help educate homeowners on the benefits of foam insulation. When Amanda isn’t writing, she’s spending time with her husband and rescued huskies. She also loves knitting, making art, cooking, and hosting dinner and a movie night for friends and family.
Silicone coatings are typically produced by adding a catalyst and solvents to a silicone base. Because the silicone is a natural material, these coatings are bio-degradable. They can be applied to a roofing system using many different techniques, including spraying or rolling. Silicone coatings are available in many colors, including reflective white and translucent.

How Much Is Closed Cell Spray Foam


I just received this and it worked well for me. It works well for small gaps (around windows, between studs), but probably not the right tool for larger gaps (>1" or 2"). If used in larger gaps, it works OK if it is layered in. Spray a little and wait for it to set, then layer another on top, etc... This is pretty much noted by the seller. It is pretty much exactly as described and priced right, so 5 stars. If you need to do larger gaps, buy 2 part.
Acrylic coatings are typically applied in two coats, with the second running perpendicular to the first. 1 gallon per 100 square feet is a good estimate for these coatings, as they do not need to be applied nearly as thick as many other coatings. These coatings can be sprayed or roll-applied. Acrylic coatings generally require a re-coat within 2-3 years of application.

I am an Architect in Toronto. I am designing a new roof addition to a row house building. Because of existing conditions and the shape of the new roof. It may be easiest to use closed cell spray foam within the areas of the joists. My question is when spray foam is used in this situation do I need to worry about how the joist members may be thermal bridges? It is not common to provide a little bit of rigid insulation to protect the joist members? The additional layer of outboard insulation will require an extra layer of plywood above the insulation which will add to cost.

How Much Spray Foam Garage


Spray polyurethan foam does effectly prevent all six of these heat transfer methods from occurring. These should be the mechanisms by which you judge insulation, in addition to their R-Value. If you're uncertain about installing spray foam insulation, Energy Star has a map that recommends levels of insulation by R-value and cost-effectiveness in the United States.
This is in great contrast to my friend's experience. Her attic spaces were sprayed and the foam is actually pretty, and I was in her attic 6-7 days after it was sprayed and could hardly smell anything when I stuck my face up to the foam. And she did not have to clean up one speck of dust during or after the spraying. I got the name/number of the guy from her who managed her attic project, but between the time he did my house and the time he did her house, he was let go from the company who did her attic and hired by another company. He assured me everything would be the same, etc., etc., and I had no reason to believe anything had changed, but the sprayers who did my house later admitted they had never sprayed an attic before and I also found out that the foam used in my attic was from a different manufacturer. Neither my friend nor I had any idea this guy was with different company then, until the week after they filled my attic with off ratio foam, and my home with toxic vapors.  
A: The RV roof coating works by waterproofing, weatherproofing and sealing our RV roofs from elements, including rain, snow, wind and other outer forces. It can also resist impact from leaves, twigs, dusts and other things that would otherwise damage the roof. It also works by reflecting UV rays, keeping the roof from degradation. The roof coating can also prevent leaks, heating and cooling loss and discomfort in our RV.
Sealection 500 is a spray-applied adhesive, which once applied, expands in place using water-blown technology, without CFCs, HCFCs, or ozone-depleting chemicals. Unlike traditional fiberglass insulation, Sealection 500 will maintain its performance; time and temperature have no effect on the spray foam insulation's R-value of 3.81 at 1 inch. Sealection 500 never deteriorates or decomposes. The product retains its shape and half-pound density over time, and never settles or compacts.
Thoroughly clean the roof surface. Roofs collect oils from asphalt, chimneys, and cars plus lots of dirt and dust. Coatings don’t stick well to any of these. We recommend cleaning with an inexpensive solution of TSP or TSP Substitute in a bucket of water (follow label instructions). Use a broom to scrub ponding areas and areas of peeling coatings. Work a section at a time and hose off the dirty water. Sweep away puddles to promote drying. Do not allow wash water to dry on walls, furniture, windows, and visible surfaces. 
In the early days of insulating attics, people believed the insulation was a heat source. That’s not the case, as the insulation is actually a barrier between two areas of different temperatures. As for the “hot roof” theory, the unvented attic system could make the temperature of the roof go up a little, but this increase won’t cause damage to your shingles.
DID YOU KNOW? Spray FOam insulation out-performs conventional insulation materials because they (conventional insulation materials) trap still-dry air and if that air moves or becomes wet, the thermal resistance can drop by 50%. Spray Foam protects against air infiltration, which can increase energy costs in buildings by 10 to 40%. Eliminate these drafts and live in a more energy-efficient, comfortable and healthier building by choosing spray foam insulation.
The drawback to spray foam insulation is it's been known to cause certain health issues such irritation of the eye and the gastrointestinal and respiratory tracts. Direct contact can cause inflammation to the skin, and some individuals have been known to break out in a rash on the arms, chest and neck area. Spray foam insulation has also been linked to a few cases of hypersensitivity pneumonitis. This condition can cause:
Silicone based coatings can be spray or roller-applied, and should utilize a medium-nap roller when rolled. These coatings are applied anywhere from 2 to 3.5 gallons per 100 square feet, depending on the substrate. Silicone has two major advantages over the other four types of coatings that should be considered when searching for the best roof coating: 1) it can resist ponding water for extended periods of time and 2) it can adhere to most substrates without a primer. Because of these two major advantages, silicone is the best roof coating that satisfies both quality and cost-effectiveness. https://www.youtube.com/watch?v=ggLAUsiuI_o&app=desktop

Wallis Spray Foam was started in 1997. We were one of the first Urethane spray foam providers in Parker and surrounding counties. Since 1997, Wallis Spray Foam has continued to provide Urethane services for residential and commercial markets in the North Central Texas area. Our company is based in Weatherford, Texas where we have a reputation of providing a professional, customer oriented service. Wallis will approach every job as its most important and complete the service in a timely manner. We only do the best quality service and no job is considered too small or too big.

I started using Gaco years ago primarily to solve ponding water Problem. It has work well, solved my problems with other roofing options and repairs as well as many other Flat roof issues.  My only problems were experienced when I did not clean the surface well enough for good adhesion.  Follow the Instructions.  Great product and highly recommended. .
Another thing we love about the Liquid Roof is its ability of not being damaged by freezing and other extreme temperatures. You will also appreciate its ability of staying flexible for a longer period of time. Did you know that it could also contract and expand as you roof moves? That is one of the things to look for when shopping around for this kind of product we found in the Liquid Roof.
I have used the Froth-Pak 200 to air-seal rim joists--the area above the foundation wall in a basement. The first time I used it I did not shake the canisters well enough and the foam did not cure properly. Don't just shake the box for a few seconds. I take the tanks out of the box so I can shake/invert each tank for a minute or two. You will be able to hear the chemical sloshing around in the tanks. Also, don't ignore the recommended temperature for application--around 75 degrees F.

The product is an acrylic coating, which is packed conveniently for ease of use. As it is also in one-gallon size, you can rely on its supreme area coverage reaching up to 125 square feet. The Dicor rubber roof coating is also very easy to apply. When shopping around for a roof coating, we believe it pays off to find an easy to apply product for fast results. It is one of the best qualities of the RV roof coating that makes it a top pick in the category.
One of the high-tech insulation products being utilized these days is a foam-spray product called "Icynene," which is a foam that starts as two liquid components (a and b, if you will) that are heated up and sent through two hoses and meet at a tip of a gun where the magic begins. This is a thin film that expands to 100 times its volume in eight seconds, when it's permanently set up.

Spray foam insulation, when properly installed is both an air barrier and when closed cell foam is used at the proper depth a vapor barrier!  Before hiring any contractor you should establish the brand of foam being used and verify that with the named manufacture.  Please ask for ESR reports and MSDS sheets on any foam being installed in your home. A couple areas where you might consider spray foam insulation include:
Repair and seal roof penetrations, tears, open seams, etc. using Elastek 103 Crack & Joint Sealant and reinforce with polyester roof fabric as necessary. In larger or deep ponding areas, apply Elastek 500 Puddle Plaster to fill in areas that hold water. Avoid using plastic roof cement. Serious ponding should be referred to a roofing contractor. Blisters in previous coatings may be opened but these areas must be allowed to dry-out completely. Blisters in the roofing ply should be left alone unless likely to break. Caulk and reinforce open seams, roof penetrations, cracks, and tears. These are potential leak points so work carefully and thoroughly. Use fabric to build flashings around roof edges or roof penetrations, and to reinforce various coating repairs. A polyester fabric is used because it will stretch with the coatings. (Fiberglas fabric is not recommended.) Fabric is normally cut to extend three inches beyond the repaired area in all directions. The coating is applied to the roof surface and the fabric is immediately pushed into the wet surface. An additional coat is applied over the fabric and the patch is allowed to dry. If your roof has stucco parapets, examine them for cracks along the sides and top. These areas often permit water to enter the wall and can cause blisters and wrinkles in the roof surface. Repair with Elastek 103 Crack & Joint Sealant. If you do not have parapets, examine the metal drip edge for a tight seal with the roof membrane. Use 4″ or 6″ roofing fabric covered under and over with Crack & Joint Sealant to seal cracks along drip edges, penetrations, and open seams. https://m.youtube.com/watch?feature=player_embedded&v=ggLAUsiuI_o
Touch ‘n Foam Pro System 600 is a completely self-contained 2-component foam system that is portable and disposable. Complete with color-coded hoses, ergonomic foam applicator, and all the necessary tools to get started, the System 600 provides up to 600 board feet* (theoretical) of polyurethane spray foam. Designed for larger insulating (up to 2 inch fills), sealing, patching and filling applications, the System 600 provides a quick, consistent flow of foam with rapid curing (60 seconds) to insulate stud wall cavities, gaps, cracks, expansion joints, and other sources of air leakage.
I don't even want to ask this question but... several years ago we hired a local contractor to spray high density foam on the roof deck and walls of our unfinished 2nd floor. We realized that the job was done poorly and cut an access into the attic space to assess things. We realize now that they spray foamed directly to the chimney (no flashing). The chimney is currently used for a woodstove and DHW venting. The DHW will go away but wood stove will remain. My question is, how bad (unsafe) is this? I have found information on foam exposure to fire but have not been able to find anything about temperature ratings in general (i.e. what happens on prolonged exposure to high temperatures). 

Roof Coating Denver Colorado

×